SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Mounting Type Approval Agency DataSheet RoHS Status REACH Status ECCN HTSUS Standard Package Breaker Type Current Rating (Amps) Voltage Rating - AC Voltage Rating - DC Actuator Type Number of Poles Illumination Illumination Voltage (Nominal)
CA2-B2-34-610-121-D Carling Technologies CA2-B2-34-610-121-D -
RFQ
ECAD 6416 0.00000000 Carling Technologies C Bulk Active Panel Mount CCC, CSA, UL, VDE download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 10A 250 V 80 V Lever 2 None -
AC2-B0-24-450-114-D Carling Technologies AC2-B0-24-450-114-D 126.6700
RFQ
ECAD 3717 0.00000000 Carling Technologies A Bulk Active Panel Mount CCC, CSA, UL, VDE download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 5A 250 V 80 V Rocker 2 None -
BA1-B0-14-210-1B1-MT Carling Technologies BA1-B0-14-210-1B1-MT -
RFQ
ECAD 5287 0.00000000 Carling Technologies B Bulk Active Panel Mount CCC, UL489A - ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 100mA 277 V 80 V Lever 1 None -
AA1-B0-34-630-321-P Carling Technologies AA1-B0-34-630-321-P -
RFQ
ECAD 9758 0.00000000 Carling Technologies A Bulk Active Panel Mount CCC, CSA, TUV, UL download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 30A 250 V 80 V Lever 1 None -
C11-B0-26-620-23A-DG Carling Technologies C11-B0-26-620-23A-DG -
RFQ
ECAD 8712 0.00000000 Carling Technologies C Bulk Active Panel Mount CCC, CSA, UL489 - ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 20A 240 V 125 V Rocker 1 None -
CA3-B0-20-610-22C-C Carling Technologies CA3-B0-20-610-22C-C -
RFQ
ECAD 5055 0.00000000 Carling Technologies C Bulk Active Panel Mount CCC, CSA, UL download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 10A 480 V 150 V Lever 3 None -
AJ1-B2-16-610-464-C Carling Technologies AJ1-B2-16-610-464-C -
RFQ
ECAD 2443 0.00000000 Carling Technologies A Bulk Active Panel Mount CCC, CSA, UL download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 10A 277 V 80 V Rocker 1 None -
CF1-B0-14-670-611-D Carling Technologies CF1-B0-14-670-611-D -
RFQ
ECAD 5210 0.00000000 Carling Technologies C Bulk Active Panel Mount CCC, CSA, UL, VDE - ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 70A 480 V 80 V Rocker 1 None -
CA1-B0-16-712-2D1-I Carling Technologies CA1-B0-16-712-2D1-I -
RFQ
ECAD 2748 0.00000000 Carling Technologies C Bulk Active Panel Mount CCC, CSA, UL1077, UL1500 download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 12.5A 480 V 80 V Lever 1 None -
CA2-B2-34-645-111-C Carling Technologies CA2-B2-34-645-111-C -
RFQ
ECAD 9563 0.00000000 Carling Technologies C Bulk Active Panel Mount CCC, CSA, UL download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 45A 480 V 125 V Lever 2 None -
BA1-B0-14-450-122-D Carling Technologies BA1-B0-14-450-122-D 46.6600
RFQ
ECAD 7654 0.00000000 Carling Technologies B Bulk Active Panel Mount CCC, CSA, UL, VDE download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 5A 277 V 80 V Lever 1 None -
CB2-B0-26-650-222-D Carling Technologies CB2-B0-26-650-222-D -
RFQ
ECAD 2296 0.00000000 Carling Technologies C Bulk Active Panel Mount CCC, CSA, UL, VDE download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 50A 250 V 150 V Lever 2 None -
CB2-B0-44-650-12A-D Carling Technologies CB2-B0-44-650-12A-D -
RFQ
ECAD 2493 0.00000000 Carling Technologies C Bulk Active Panel Mount CCC, CSA, UL, VDE download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 50A 250 V 150 V Lever 2 None -
AC1-B0-24-635-531-C Carling Technologies AC1-B0-24-635-531-C -
RFQ
ECAD 1487 0.00000000 Carling Technologies A Bulk Active Panel Mount CCC, CSA, UL download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 35A 277 V 80 V Rocker 1 None -
CG2-B2-24-650-231-C Carling Technologies CG2-B2-24-650-231-C -
RFQ
ECAD 9321 0.00000000 Carling Technologies C Bulk Active Panel Mount CCC, CSA, UL - ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 50A 480 V 150 V Rocker 2 None -
AA2-B0-44-645-5B1-C Carling Technologies AA2-B0-44-645-5B1-C -
RFQ
ECAD 7463 0.00000000 Carling Technologies A Bulk Active Panel Mount CCC, CSA, UL download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 45A 277 V 80 V Lever 2 None -
CA2-B0-24-425-231-CG Carling Technologies CA2-B0-24-425-231-CG -
RFQ
ECAD 5660 0.00000000 Carling Technologies C Bulk Active Panel Mount CCC, CSA, UL489 - ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 2.5A 240 V 150 V Lever 2 None -
CA1-B0-12-680-331-H Carling Technologies CA1-B0-12-680-331-H -
RFQ
ECAD 6719 0.00000000 Carling Technologies C Bulk Active Panel Mount CCC, CSA, UL489, VDE download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 80A 480 V 80 V Lever 1 None -
BA2-B0-26-650-511-A Carling Technologies BA2-B0-26-650-511-A -
RFQ
ECAD 2441 0.00000000 Carling Technologies B Bulk Active Panel Mount - - ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 50A 277 V 80 V Lever 2 None -
AA2-B0-12-620-1B1-C Carling Technologies AA2-B0-12-620-1B1-C -
RFQ
ECAD 5207 0.00000000 Carling Technologies A Bulk Active Panel Mount CCC, CSA, UL download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 20A 277 V 80 V Lever 2 None -
AN1-B0-32-450-533-I Carling Technologies AN1-B0-32-450-533-I -
RFQ
ECAD 8719 0.00000000 Carling Technologies A Bulk Active Panel Mount CCC, CSA, UL1077, UL1500 download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 5A 250 V 65 V Push to Reset 1 None -
CA1-B4-14-650-121-C Carling Technologies CA1-B4-14-650-121-C -
RFQ
ECAD 4685 0.00000000 Carling Technologies C Bulk Active Panel Mount CCC, CSA, UL download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 50A 480 V 125 V Lever 1 None -
AF2-B0-21-610-233-C Carling Technologies AF2-B0-21-610-233-C -
RFQ
ECAD 6695 0.00000000 Carling Technologies A Bulk Active Panel Mount CCC, CSA, UL download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 10A 277 V 80 V Rocker 2 None -
FA1-B0-14-820-12B-BG Carling Technologies FA1-B0-14-820-12B-BG -
RFQ
ECAD 1136 0.00000000 Carling Technologies F Bulk Active Chassis Mount CCC, cULus, UL489 download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 200A 277 V 125 V Lever 1 None -
CA3-B9-26-613-121-CG Carling Technologies CA3-B9-26-613-121-CG 246.2500
RFQ
ECAD 8577 0.00000000 Carling Technologies C Bulk Active Panel Mount CCC, CSA, UL489 - ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 13A 240 V 150 V Lever 3 None -
AA3-B0-34-615-381-C Carling Technologies AA3-B0-34-615-381-C -
RFQ
ECAD 5844 0.00000000 Carling Technologies A Bulk Active Panel Mount CCC, CSA, UL download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 15A 277 V 80 V Lever 3 None -
CA1-B2-44-450-122-D Carling Technologies CA1-B2-44-450-122-D -
RFQ
ECAD 3172 0.00000000 Carling Technologies C Bulk Active Panel Mount CCC, CSA, UL, VDE download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 5A 250 V 150 V Lever 1 None -
AG1-B0-24-620-413-D Carling Technologies AG1-B0-24-620-413-D -
RFQ
ECAD 5334 0.00000000 Carling Technologies A Bulk Active Panel Mount CCC, CSA, UL, VDE download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 20A 250 V 80 V Rocker 1 None -
CA3-B0-24-630-622-D Carling Technologies CA3-B0-24-630-622-D -
RFQ
ECAD 3612 0.00000000 Carling Technologies C Bulk Active Panel Mount CCC, CSA, UL, VDE download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Magnetic (Hydraulic Delay) 30A 250 V 150 V Lever 3 None -
AF2-A0-03-650-5B3-C Carling Technologies AF2-A0-03-650-5B3-C -
RFQ
ECAD 1086 0.00000000 Carling Technologies A Bulk Active Panel Mount CCC, CSA, UL download ROHS3 Compliant REACH Unaffected EAR99 8536.20.0020 1 Switch Only 50A 277 V 80 V Rocker 2 None -
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse